Explosion proof slip ring: providing a safe and reliable solution for rotating transmission in hazardous environments

In hazardous industrial environments such as petroleum, natural gas, mining, and chemical industries where flammable and explosive gases or dust exist, electrical safety of equipment is crucial. Explosion proof slip ring, as a high safety and high reliability rotating connection device, is specially designed for such explosive environments to ensure that it does not become a detonation source while transmitting power and signals.

Jiujiang Ingiant Technology Co., Ltd., with its profound technical accumulation and rich development and production experience in the field of explosion-proof slip rings, can provide customers with one-stop services from standard products to customized solutions. The products have been certified by the national authoritative explosion-proof organization and are committed to safeguarding the safe operation of high-risk industries worldwide.

Ⅰ. Classified by explosion-proof type

Explosion proof type (Ex d): This is our most core explosion-proof type. The product will completely enclose components that may generate sparks or arcs within a sturdy casing. The shell can withstand internal explosions without damage and effectively prevent flames from spreading to the external environment. Our explosion-proof products are electrical equipment suitable for Class IIC environments and can cover the usage conditions of Class IIA and IIB equipment. Some of the product cases we have worked on include DHK195F-20 and DHS150F-4-100A. You can click on the hyperlink to browse more product information.

Dust explosion-proof type (Ex t): specially designed for explosive dust environments (such as metal dust, coal powder, agricultural and sideline product dust, etc.). By optimizing the structural design, the intrusion of explosive dust is effectively prevented, and the anti explosion and explosion-proof capabilities of the equipment are improved. Some of the product cases we have worked on include DHK038F-22-10A. You can click on the hyperlink to browse more product information.

Intrinsic safety type (Ex i): By limiting the energy of the circuit, it ensures that it does not generate sparks or thermal effects sufficient to ignite ambient gases under normal operation and fault conditions, fundamentally guaranteeing safety. Some of the product cases we have worked on include HDC15-29. You can click on the hyperlink to browse more product information.

In addition, our explosion-proof slip ring can meet the dual requirements of explosive gas environment and explosive dust environment, and is suitable for more complex hazardous working conditions.

. Classified by structural form

DHK through-hole: The center of the slip ring is equipped with a through hole, which facilitates the installation of hydraulic, pneumatic, or transmission shaft components. This type of product has a wide range of applications and can provide multiple specifications for different aperture sizes (such as 12.7mm to 165mm, etc.).

DHS Capsule: With a compact appearance and high design accuracy, it is suitable for precise signal transmission in small and medium-sized systems.

Pancake: A flat design designed to provide a solution for situations where axial installation space is limited.

High current type: designed for high-power application scenarios such as welding, electroplating, generator sets, cable reels, etc., capable of carrying high current transmission. 

Customized type: It can combine multiple media such as power, signal, data, optical fiber, etc. according to the special needs of customers, and provide customized functions such as high speed and high temperature resistance.

. Classified by explosion-proof level

Explosion proof rating is a key indicator to ensure the safe use of equipment in specific hazardous areas. Our products cover the following core ratings:

Gas group: The product reaches the IIC level, which is the highest gas group and can be used under both IIA and IIB equipment conditions.

Temperature group: T6 group provides the highest safety level, with the highest surface temperature of the equipment not exceeding 85 ℃, which can meet the requirements of all temperature group environments from T1 to T6.

Equipment Protection Level (EPL): Provides Gb (high protection level, suitable for Zone 1 and Zone 2) and other level products.

Protection level (IP): Provides multiple high protection levels such as IP66, IP67, and even IP68 to ensure stable operation in harsh dust and waterproof environments.

Explosion proof markings such as “Ex d IIC T6 Gb” clearly indicate that the product is explosion-proof, suitable for IIC gas environments, with a maximum surface temperature that meets the T6 group and a high protection level (Gb).

. Core application scenarios of explosion-proof slip rings

Jiujiang Ingiant Technology Co.,Ltd explosion proof slip rings are essential safety components in many high-risk industries, and the global market demand continues to grow. Its main application areas include:

The oil and gas industry (accounting for approximately 41% of global market demand)

This is the largest application market for explosion-proof slip rings. The product is widely used in:

Offshore oil drilling platforms, onshore drilling equipment

Natural gas pipelines, liquefied natural gas (LNG) ships

Refineries and various petrochemical facilities

Mining and metallurgical industry (accounting for approximately 32% of global market demand)

The mining industry is the second largest application area. The product is widely used in:

Underground mining equipment, coal mining machinery

Mining cable drum

Various types of rotating equipment that require operation in high dust and explosive gas environments

We will attend the ELECTRA MING AFRICA 2026 exhibition at the Johannesburg International Exhibition Center from September 7th to 11th, 2026. Our booth is located in Hall 2-F31, and we look forward to the opportunity to meet you at the exhibition.

Chemical and pharmaceutical industries (accounting for approximately 27% of global market demand)

The demand for explosion-proof slip rings in the chemical industry is also significant. The product is widely used in:

Chemical equipment, industrial reaction kettle

Explosive material packaging equipment

Drying, mixing and other processing equipment

Other important application areas

Engineering machinery and ports: such as cranes, winches, and offshore lifting systems.

General Industry and Environmental Protection: Spray painting equipment, agricultural and grain processing equipment, wastewater treatment systems, etc.

In the field of new energy, some explosion-proof slip rings are also used in equipment such as wind turbines.

. Why choose us

Authoritative certification: Ingiant explosion-proof slip ring have passed the strict certification of the national authoritative explosion-proof organization (Nanyang Explosion proof Electrical Research Institute) and obtained the explosion-proof qualification certificate.

Dual protection: The product can simultaneously meet the requirements of explosive gas environment and explosive dust environment, with stronger adaptability.

High reliability design: adopting high-strength stainless steel shell, high-performance precious metal contacts, and high sealing structure to ensure stable operation in extreme environments.

Full scene coverage: Provides various structures from through-hole, cap type to disc type, high current type, etc., covering all temperature groups of T1~T6 and protection levels of IP65~IP68, meeting diverse needs.

Customized service: We can provide customized solutions for the combined transmission of multiple media such as power, signal, data, fiber optic, RF high-frequency joints, etc. according to the specific working conditions of customers.

If you are looking for a highly reliable rotary transmission solution suitable for hazardous environments, please feel free to contact us at any time. Our technical team will recommend the most suitable product for you based on your specific working conditions and explosion-proof level requirements.

DHK220F-20-10A-3 (1)

设计流程

 

 

 

 

 


Post time: Jul-31-2026